HomeProductsHSS572-phase Hybrid Stepper Servo Driver
2-phase Hybrid Stepper Servo Driver
//www.soyamotor.com/uploadfiles/107.151.154.230/webid1488/source/202008/159727804263.jpg
  • Hybrid stepper motor driver

2-phase Hybrid Stepper Servo Driver

HSS57 is 2 phase nema 23 series hybrid stepper servo driver. It adopts new
generation 32 bit DSP and vector control technology, which can avoid the stepper
motor losing steps and ensure the accuracy of the motor.

1. Instruction

1.1 Overview

HSS57 is 2 phase nema 23 series hybrid stepper servo driver. It adopts new generation 32 bit DSP and vector control technology, which can avoid the stepper motor losing steps and ensure the accuracy of the motor. The torque reducing is much lower than open loop stepper motor when it is at higher speed. The high speed performance and torque are enhanced in a great extent. Meanwhile the current control is based on the load, that can reduce the motor temperature rising effectively, then can extend the using life of the motor. The build-in place in position and alarm output signal can help the upper monitor to monitor and control. The function of position ultra difference alarm can ensure the machine work safely. The closed loop system is an ideal improvement and a good replacement of open loop system, Besides that, it also have some function ofAC servo motors, but price is just half ofAC servo.


1.2 Features

1.2.1 Stepper motor closed loop system, never lose step.

1.2.2 Improve motor output torque and working speed.

1.2.3Automatic current adjustment based on load, lower temperature rising.

1.2.4 Suitable for all mechanical load conditions (include low rigidity belt pulley and

wheel), no need to adjust gain parameter.

1.2.5 Motor work smoothly and low vibration, high dynamic performance at

acceleration and deceleration.

1.2.6 No vibration from high speed to zero speed

1.2.7 Drive nema 23 series 2N.m closed loop stepper motor.

1.2.8 Pulses response frequency can reach 200KHZ

1.2.9 16 kinds microsteps choice, highest 51200microsteps/rev.

1.2.10 Voltage range: DC24V~50V

1.2.11 Over-current, over-voltage and position ultra difference protection function.


1.3Applications

Closed loop stepper system can be applied to all kinds small automatic equipment and Instruments, such as engraving machine, special industrial sewing machine, stripping machine, marking machine, Dispensing machine, cutting machine, laser phototypesetting, graph plotter, NC machine, automatic, assembly equipment and so on.


2. Electrical, mechanical, environment Parameter

2.1 Electrical Parameter

Voltage range

DC24~50V

Peak current

Peak 6.0A(current change according to load)

Logic input current

7~20mA

frequency

0~200KHz

Suitable motor

57HSE2N

Encoder lines

1000

Insulation resistance

>=500MΩ


2.2 Environment Parameter

Cooling method

Natural or radiator

Operating

environment

Operating Occasions

try to avoid dust, oil, corrosion gas

Operating temprature

0~50℃

Operating humidit

40~90%RH

virbration

5.9m/s²Max

Storage temperature

-20℃~65℃

Weight

About 560g


2.3 Installation Dimension

未标题-2.jpg

3.Driverconnector,indicatorandwiringdiagram

3.1motorandpowersupplyinputport

PortNO.

MotorWirecolor

1

A+

Aphasewinding+

red

2

A-

Aphasewinding-

green

3

B+

Bphasewinding+

yellow

4

B-

Bphasewinding-

blue

5

+Vdc

Inputvoltage

DC24~50V

6

GND


3.2.Encoderinputport

PortNO.



EncoderWirecolor

1

EB+

EncoderBphaseinput+

yellow

2

EB-

EncoderBphaseinput-

green

3

EA+

EncoderAphaseinput+

black

4

EA-

EncoderAphaseinput-

blue

5

VCC

Encodervoltage+5V

red

6

EGND

EncoderGrand0V

white

(The encoder wires misconnected will lead to the damage of driver or encoder.)

3.3Signalcontrollerport

PortNO.




1

PUL+

Pulseinput+

Ifthesignalcontrolvoltageis

+5V,thenthesignalcontrol

inputportdonotneedto

connectanextraresistance.If

thesignalcontrolvoltageis

+12V,thenthesignalcontrol

inputportneedtoconnecttoa

1Kresistance.Ifthesignal

controlvoltageis+12V,then

thesignalcontrolinputport

needtoconnecttoa2K

resistance.

2

PUL-

Pulseinput-


3

DIR+

Directioninput+


4

DIR-

Directioninput-


5

ENA+

Enableinput+


6

ENA-

Enableinput-


7

ALM+

Alarmsignaloutput+

OCoutput,thereisalarmsignal

whenclosed,noalarmsignal

whenopencircuit.


3.4Switchsetting
SW1:NC.
SW2:Rotate direction setting.on=CW,off=CCW.
SW3、SW4、SW5、SW6:Microstep setting

Micorstep/rev

SW3

SW4

SW5

SW6

Default400

on

on

on

on

800

off

on

on

on

1600

on

off

on

on

3200

off

off

on

on

6400

on

on

off

on

12800

off

on

off

on

25600

on

off

off

on

51200

off

off

off

on

1000

on

on

on

off

2000

off

on

on

off

4000

on

off

on

off

5000

off

off

on

off

8000

on

on

off

off

10000

off

on

off

off

20000

on

off

off

off

40000

off

off

off

off


3.5Statusindication
PWR:power indicator light : When power is on, the green light is on.
ALM:Alarm indicator light: If the red light is flicker one time within 3 seconds, that means over current or interphase short circuit; If the red light is flicker twice within 3 seconds, that means over voltage; if the red light is flicker three times within 3 seconds, that means position ultra difference or the encoder connector is disconnected.

3.6Wirediagram

1.jpg

3.7WiresforEncoder
Standard wire length for encoder is 2 meters. ( Wire length can be customized.)


Inquire Now
Name *
Mobile Phone (WhatsApp)
Email *
Message *
Verification code*
  
Related products
Related news
Other products
Hot products
CopyRight © 2020-2024   Changzhou Soya Motor Control Factory  All rights reserved    Sitemap  All tags